Skip to Main Content
IBM Sustainability Software - Ideas Portal


This portal is to open public enhancement requests against the products and services belonging to IBM Sustainability Software. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

Status Submitted
Created by Guest
Created on Apr 21, 2026

Improve Downtime Loss Identification in Tahoe UI

Title

Enhance downtime loss analysis by incorporating Daily Energy alongside Active Power & POA Irradiance

Background / Problem Statement

Currently, in the Tahoe UI under Downtime and Alarms Correlation, we visualize:

  • Active Power (Inverter)
  • POA Irradiance (WMS)

While this helps identify when an inverter is not producing despite irradiance availability, it provides an incomplete diagnostic picture.

👉 The limitation:

  • A drop in Active Power with available irradiance suggests downtime
  • But it does not clarify the root cause, such as:
    • Inverter failure
    • Communication/data loss issue
    • Grid outage
    • Curtailment or external constraint

This leads to ambiguity in downtime classification.

Proposed Enhancement

Add Daily Energy (Cumulative Energy Generation) to the same visualization.

How it helps

  • If inverter is truly down → Daily Energy curve becomes flat (constant)
  • If it's a communication/data issue →
    • Active Power may drop to zero
    • But Daily Energy continues increasing
  • If partial issues → slope change in Daily Energy provides insights

Expected Behavior

On the same time-series chart:

  • Overlay or add a third axis/line:
    • Daily Energy (kWh)
Idea priority Medium