Skip to Main Content
IBM Sustainability Software - Ideas Portal


This portal is to open public enhancement requests against the products and services belonging to IBM Sustainability Software. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Clear

Ideas

Showing 81 of 7027

DOORS Next Delta Monitoring Task (DMT) should be able to be tracked outside of the UI and also alert Jazz admins if it falls behind

Multiple Customers will benefit with this functionality as it is essential for Customers to be able to monitor the health of the DOORS Next TRS Feed, without having to manually check its status. If should be configurable so if the feed falls behin...
11 days ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration

Enable Sorting of Artifact Attributes Within Defined Artifact Types

Currently, DOORS Next supports sorting for Enumerated Attribute Data Types, allowing values or labels to be sorted in ascending or descending order. To improve usability and consistency across artifact management, we request that this sorting capa...
about 1 month ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration

Capture clean user access log for respective DNG project areas

We are looking to obtain a list of users who have accessed a particular project in DNG (for cleanup and security purposes). We have tested the options provided in the technote below: https://www.ibm.com/docs/en/engineering-lifecycle-management-sui...
17 days ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration

Can MAS auto adjust to the width of the screen used?

All our end users are complaining that they have to scroll both up and down and sideways. Often the buttons in need of pushing to get to the next page or next record or even required fields in need of populating are hidden outside of view. The aut...
3 months ago in IBM MAS - Oil & Gas / HSE 0 Planned for future release

Auto-lock the Lock number when PTW / isolation certificate status changes to Isolation Complete

Auto-lock the Lock number when PTW / Isolation Certificate status changes to Isolation Complete. Currently users have to lock the lock number manually by clicking on the lock check box, it should be auto checked the field "PLUSGPTWLCKTGOP.LOCKAPPL...
3 months ago in IBM MAS - Oil & Gas / HSE 2 Planned for future release

De-isolation is not allowed if another PTW is using the same location as an isolation point

If 2 independent permit to works are using the same location as an isolation point in Lock Out Tag Out Operations, the isolation cannot be removed until the work in both permits is completed. System is giving below error while try to de-isolate an...
3 months ago in IBM MAS - Oil & Gas / HSE 4 Under review

Improved use of ANY on link constraints

When using ANY in a link constraint as the source artifact type, users should be able to select artifact types from all components assiciated with the current component through the same global configuration.
about 2 months ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration

Avoid Read access to a folder and to a module to some members

In DOORS Next, everyone declared at PA or TA level has a read access to every artifacts in a Project Area. DOORS Next offers to assign ownership to a Team for a folder or at module level. This means read-write access. BUT other members (at PA leve...
over 1 year ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration

Project, Component and Folder level Access control granularity

What we need from DOORS NEXT is: Project-Level Access Control granularity: DOORS NEXT already supports this. No further enhancement, requested at this point. Component-Level Access Control granularity: Granting READ only permissions to a user to a...
over 2 years ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration

Review managing and administration

When we conduct a review, for example a collection of requirements relating to performance, in person during a meeting, in the presence of performance specialists, the participants in this review are either reviewer or validator.To secure this rev...
about 2 years ago in IBM Engineering - Requirements Management DOORS Next / Administration 0 Future consideration